1. Operating Temperature Range: (-30— 105) º C
2. Store Temperature Range: (-40— 120)º C
3. Operating R. Speed: 300— 4200r/min.
4. Fly Wheel Magnetic Intensity: (1500— 1900)Gauss
Ignition Feature
1. Testing Condition: 20º C environment, Clearance between fly wheel is (0.4± 0.1)mm and the distance of three-point is 6mm
2. Min. Continuous Ignition R. Speed ¡Ü300rpm
3. Min. Open Circuit Voltage: ¡Ý12KV/300rpm; ¡Ý16/KV(1000— 4200)rpm.
4. Ignition Advance Angle: (22-25)° /(300— 4200)rpm.
5. When R. Speed is 2000rpm, lubricating oil senser is cut off as soon as grounding. The engine flameouts during 3 to 10 seconds.
6. On Flameout Line is granding, its flameout during 1 second.
Performance
1. Temperature Performance: During (-29— 125)º C, keep each temperature for one hour and continue 25 cycles, the original Performance keeps above 90%
2. Endurance Performance: The temperature 85 and R. Speed 3600rpm, Continue 150 hours operating, the original Performance keeps above 90%
3. Open Circuit Performance: Temperature 85º C and R. Speed 3600rpm, after continue 150 hours, secondary open circuit keeps above of 90% original one.
4. Shake Performance: 4 hours shock on tridimensional direction and strength is 98m/(second*second), the range of frequency sweep is 50— 500Hz. The original performance keeps above 90%